Parsed SWM report

17 & 19 Ann Street

10 West - 17 & 19 Ann Street, 84 & 90 High Street · Redevelopment · 2024-06-27

Consultant: Urbantech Consulting, A Division of Leighton-Zec West Ltd. Model: UNKNOWN Revision: Issued for 4th OPA/ZBL Submission
Credit scorecard — Mississauga bylaw

Each category awards a maximum percentage of the annual stormwater charge as credit. Evidence is extracted directly from the source PDF — no manual review.

Peak Flow
only some design storms documented
40%
Water Quality
TSS removal 80% (enhanced)
30%
Runoff Volume
water balance retains 5 mm on site (2% per mm, max 30% at 15 mm)
30%
Operations
combinable O&A sub-credits — not documented
0%
Net credit
Capped at 50% of annual stormwater charge
50%
Pre vs post peak discharge
Storm eventPre-dev (m3/s)Post-dev (m3/s)Δ
10-yr0.0460.046+0%
100-yr0.0810.026−68%
Stormwater controls (3)
Underground storageConcrete Cistern / Underground Storage Tank
Storage volume89.0 m³
Treatment volume89.0 m³
Outletorifice
100-yr HGL80.78 m

Active storage provided = 89 m³, required = 80.64 m³. Dead storage provided = 26.15 m³, required = 16.5 m³. Tank area = 87.18 m², height = 1.32 m. 100 mm orifice tube proposed. Tank to be pumped. Located within underground parking garage.

Oil-grit separatorOGS1 - Stormceptor EFO4

Located downstream of storage tank within parking garage. Provides 91% estimated net annual TSS load reduction. Target TSS removal 80%. Upstream orifice control flow rate = 26 L/s. Drainage area = 0.28 ha.

SwaleTemporary Swale

Temporary swale to be removed upon final park grading. Referenced on grading plan.

Best management practices (4)
Underground storage tank (concrete cistern)Stormceptor EFO4 oil-grit separatorTemporary swale5 mm retention for reuse
Site characteristics & report metadata
Project10 West - 17 & 19 Ann Street, 84 & 90 High Street
Project typeRedevelopment
Developer10 West GO GP Inc.
PermitOZ OPA 22-3
Existing land useresidential
Proposed land usehigh-density residential (23-storey)
Site area0.33 ha
Water balance capture5.0 mm
TSS removal target80%
Allowable release rate46.0 L/s
Quality control methodOil-grit separator (Stormceptor EFO4) downstream of underground storage tank providing minimum 80% TSS removal (Enhanced Level 1)
Extraction audit
Confidence: high Completeness: 92% Source: 92-page PDF Extractor: PARCELFLOW v1 Validation: passed
Source PDF: Functional-Servicing-and-Stormwater-Report%E2%80%93OZOPA-22-3-W1%E2%80%93August-2024.pdf (92 pages) Open source PDF →
Starter package
Download credit application package »
10-page PDF: pre-filled Form 2703, starter P.Eng report skeleton, submission checklist. Engineer reviews, adds site inspection + O&M plan, certifies + submits.
Download PDF »

How to read this page. Every value above was extracted from the source PDF by the PARCELFLOW report parser, which combines a layout-robust template detector with a validated extraction stage tuned to Ontario Functional Servicing and Stormwater Management reports. The four-category scorecard maps the parsed evidence onto Mississauga's credit bylaw. Numbers are estimates — engineering review still required before submitting a formal credit application to the City.